| 1) Scope |
This specification is applicable to the technical requirements for Super Heavy Duty Battery. |
| 2) Cross References & Approximate Weight |
|
ATC
|
IEC
|
JIS
|
GB (CHINA)
|
OTHER
|
WEIGHT
|
NOMINAL CAPACITY
|
|
R03S
|
R03
|
SUM-4
|
R03
|
AAA
|
7.9 g
|
170 mAh
|
|
R6G
|
R6P
|
SUM-3
|
R6P
|
AA/HP7
|
15.0 g
|
420 mAh
|
|
R14G
|
R14P
|
SUM-2
|
R14P
|
C
|
45.0 g
|
2000 mAh
|
|
R10G
|
420P
|
SUM-1
|
R20P
|
D
|
89.0 g
|
3000 mAh
|
|
| 3) Purpose |
To assure that SUPREME POWER battery will fulfill, and customs can understand this specification. |
| 4) Reference Document |
| IEC60086 - 1:2000 |
Primary Batteries - Part 1: General |
| IEC60086 - 2:2000 |
Primary Batteries - Part 2: Physical and Electrical Specifictaion |
| GB/T 7112-1998 |
Zinc-Maganese Dry Batteries of R03, R1, R06, R14, and R20 Alkaline Sinc-Manganese Dry Batteries of LR03, LR1, LR6, LR14, and LR20 |
|
| 5) Chemical System |
Zinc-Manganese Dioxide (Zinc Chloride Electrolyte) Mercury and Cadmium <1ppm |
| 6)Nominal Voltage |
1.5 V |
| 7) Outer Wrapping |
PVC or Aluminimum Lable |
| 8) Nominal Capacity |
See (2) Conditions: 3.9() discharge 24 Hrs per day at 20+- 2 degree C end point voltage is 0.9V |
| 9) Electrical Characteristics |
| |
Off-Load Voltage (V)
|
On-Load Voltage (V)
|
Short Circuit Current (A)
|
Acceptance Standard
|
|
L03
|
L06
|
L14
|
L20
|
L03
|
L06
|
L14
|
L20
|
L03
|
L06
|
L14
|
L20
|
|
Initial within 30 days
|
1.60
|
1.60
|
1.60
|
1.60
|
1.45
|
1.50
|
1.51
|
1.53
|
3.50
|
4.50
|
5.50
|
7.00
|
GB2828 Commonly I Sampling AQL-.04
|
|
After 12 months
|
1.50
|
1.56
|
1.55
|
1.55
|
1.40
|
1.48
|
1.48
|
1.49
|
2.50
|
4.00
|
5.00
|
6.00
|
|
| 10) Service Time |
|
Model
|
Dishcarge Condition
|
Average Minimum Discharge Time
|
| |
Discharge Load
|
Daily Discharge Time
|
End of Voltage
|
IEC Standard
|
Initial with 30 days
|
After 12 Months at 20 +- 2°C
|
|
R03P
|
75
|
4 Hours
|
0.9
|
20 Hours
|
24.5 Hours
|
22.5 Hours
|
|
5.1
|
4m/h-8h/d
|
0.9
|
45 min
|
88 min
|
80 min
|
|
10
|
1 Hour
|
0.9
|
1.4 Hours
|
2.7 Hours
|
2.5 Hours
|
|
3.6
|
15 sec/min
|
0.9
|
120 Cycles
|
195 Cycles
|
170 Cycles
|
|
3.9
|
24 Hours
|
0.9
|
/
|
38 min
|
/
|
|
R06P
|
43
|
4 Hours
|
0.9
|
27 Hours
|
29.5 Hours
|
26.5 Hours
|
|
3.9
|
1 Hour
|
0.9
|
60 min
|
140 min
|
125 min
|
|
10
|
1 Hour
|
0.9
|
4.0 Hours
|
6.2 Hours
|
5.6 Hours
|
|
1.8
|
15 Sec/min
|
0.9
|
75 Cycles
|
160 Cycles
|
140 Cycles
|
|
3.9
|
24 Hours
|
0.9
|
/
|
95 min
|
80.0 min
|
|
R14P
|
3.9
|
24 Hours
|
0.9
|
/
|
310 Min
|
280 min
|
|
3.9
|
4m/h-8h/d
|
0.9
|
300 min
|
415 min
|
380 min
|
|
3.9
|
1 Hour
|
0.8
|
288 min
|
420 min
|
360 min
|
|
6.8
|
1 hour
|
0.9
|
540 min
|
790 min
|
700 min
|
|
20
|
4 Hour
|
0.9
|
30 Hours
|
40 Hours
|
35 Hours
|
|
R20P
|
10
|
4 Hour
|
0.9
|
35 Hours
|
3.6 Hours
|
32.0 Hours
|
| |
3.9
|
1 Hour
|
0.9
|
13 Hours
|
13.0 Hours
|
12.0 Hours
|
| |
2.2
|
1 Hour
|
0.8
|
6 Hours
|
7.0 Hours
|
6.2 Hours
|
| |
3.9
|
24 Hours
|
.09
|
/
|
620 min
|
/
|
Condition: Test Temperature 20 =-/2C test within 30 days fromsample receipt
Acceptance: (1) 9 Pieces of sample will be tested for each discharge condition
(2) The result of the average discharged time from each discharge condition shall be equal to or more than the average minimum time requirement. |
|
| (11) Electrolyte Leakage Proof Characteristics |
|
R03P R06P R14P R20P
|
Item
|
Condition
|
Period
|
Characteristics
|
Acceptance Standard
|
|
Over-discharge characteristics
|
3.9 ohm continuous discharge at 20 +-/2C, relative humidity: 60 +-/-15% RH
|
E.P.V. +0.35V
|
There shall be no deformation exceeding the specified dimensions, nor leakage recognized by human eye
|
N=9
Ac=0
Re=1
N=40
AC=1
Re=2
|
|
Storage Characteristics
|
45+-/-2C<65% RH
|
90 Days
|
| |
At Room Temperature
|
12 Months
|
|
| (12) Safety Standards |
|
R03P R06P R14P R20P
|
Item
|
Condition
|
Period
|
Characteristics
|
Acceptance Standard
|
|
Short Circuit Characteristics
|
Temperature;
20+-/2 C
|
24 Hours
|
There shall be no explosion of battery
|
N=5
Ac=0
Re=1
N=20
AC=0
Re=1
|
|
Abusive Characteristics
|
|
|